Site icon KerKer 的模組世界

[Juniper] Junos消除”Management Ethernet Link Down”告警

&NewLine;<p class&equals;"wp-block-paragraph"> 邊做邊學,順便留個筆記,若有錯誤請不吝指教。 <&sol;p>&NewLine;&NewLine;&NewLine;&NewLine;<p class&equals;"wp-block-paragraph"> Junos基本操作及root密碼設定可參考我之前的文章:<a href&equals;"https&colon;&sol;&sol;kerker&period;website&sol;juniper-junos&percnt;E5&percnt;9F&percnt;BA&percnt;E6&percnt;9C&percnt;AC&percnt;E6&percnt;93&percnt;8D&percnt;E4&percnt;BD&percnt;9C&percnt;E3&percnt;80&percnt;81root&percnt;E5&percnt;AF&percnt;86&percnt;E7&percnt;A2&percnt;BC&percnt;E8&percnt;A8&percnt;AD&percnt;E5&percnt;AE&percnt;9A&sol;">Juniper Junos基本操作、root密碼設定<&sol;a><&sol;p>&NewLine;&NewLine;&NewLine;&NewLine;<p class&equals;"wp-block-paragraph">&NewLine;&NewLine;所有Juniper相關文章列表:<a href&equals;"https&colon;&sol;&sol;kerker&period;website&sol;juniper-junos-&percnt;E7&percnt;B3&percnt;BB&percnt;E5&percnt;88&percnt;97-&percnt;E6&percnt;96&percnt;87&percnt;E7&percnt;AB&percnt;A0&percnt;E5&percnt;88&percnt;97&percnt;E8&percnt;A1&percnt;A8&sol;">Juniper JunOS 系列文章列表<&sol;a><&sol;p>&NewLine;&NewLine;&NewLine;&NewLine;<&excl;--more-->&NewLine;&NewLine;&NewLine;&NewLine;<p class&equals;"wp-block-paragraph">Juniper的Switch有提供一個Management的介面&lpar;interface&rpar;,當系統偵測到該介面為down時就會出現&&num;8221&semi;Management Ethernet Link Down&&num;8221&semi;告警&lpar;alarm&rpar;<&sol;p>&NewLine;&NewLine;&NewLine;&NewLine;<p class&equals;"wp-block-paragraph">如果沒有規劃要使用Management介面做管理的話建議可以關閉這個alarm以避免因alarm燈常量而忽略了其他的新出現的alarm。<&sol;p>&NewLine;&NewLine;&NewLine;&NewLine;<p class&equals;"wp-block-paragraph">首先可以先使用已下指令確定告警內容:<&sol;p>&NewLine;&NewLine;&NewLine;&NewLine;<pre class&equals;"wp-block-code"><code> root> show chassis alarms &NewLine; 1 alarms currently active&NewLine; Alarm time Class Description&NewLine; 2015-02-12 14&colon;29&colon;21 UTC Major Management Ethernet Link Down<&sol;code><&sol;pre>&NewLine;&NewLine;&NewLine;&NewLine;<p class&equals;"wp-block-paragraph">如果內容與上述內容相同則確定為管理介面為連接告警,可以在設定模式下輸入下列指令後commit:<&sol;p>&NewLine;&NewLine;&NewLine;&NewLine;<pre class&equals;"wp-block-code"><code> root&num; set chassis alarm management-ethernet link-down ignore &NewLine; root&num; commit&NewLine; configuration check succeeds&NewLine; commit complete<&sol;code><&sol;pre>&NewLine;&NewLine;&NewLine;&NewLine;<p class&equals;"wp-block-paragraph">&NewLine;&NewLine;更多關於commit指令的內容可以參考:<a href&equals;"https&colon;&sol;&sol;kerker&period;website&sol;juniper-junos&percnt;E6&percnt;8F&percnt;90&percnt;E4&percnt;BA&percnt;A4&percnt;E8&percnt;A8&percnt;AD&percnt;E5&percnt;AE&percnt;9Acommit&sol;">Juniper Junos提交設定&lpar;commit&rpar;<&sol;a><&sol;p>&NewLine;&NewLine;&NewLine;&NewLine;<p class&equals;"wp-block-paragraph">完成後可以再次使用第一個指令確定alarm已經消除,而alarm指示燈應該業會恢復正常了!<&sol;p>&NewLine;&NewLine;&NewLine;&NewLine;<p class&equals;"wp-block-paragraph">可以用show指令查看新增的設定檔:<&sol;p>&NewLine;&NewLine;&NewLine;&NewLine;<pre class&equals;"wp-block-code"><code> root> show configuration chassis &NewLine; alarm &lbrace;&NewLine; management-ethernet &lbrace;&NewLine; link-down ignore&semi;&NewLine; &rcub;&NewLine; &rcub;<&sol;code><&sol;pre>&NewLine;

Exit mobile version